Commercial Ada Shower Grab Bar Height

Grab bars shall be installed 6 inches 150 mm maximum from adjacent walls.
Commercial ada shower grab bar height. Each grab bar shall be installed 15 inches 380 mm maximum from the head end wall and 12 inches 305 mm maximum from the control end wall. Ada standards for accessible design can be downloaded from www ada. The controls and spray unit shall be within 18 inches 455 mm of the front of the shower. The ada standards do not require this grab bar but allow a second grab bar to be within the 12 clearance above the horizontal grab bar 609 3 if there is a separation of 1 min.
Or for answers to. Recessed dispensers are allowed within the 12 305 mm space above and 1 38 mm space below and at the end of a grab bar for ada the recessed dispenser must be flush. Grab bars shall not be provided above the seat. For information about the ada including the revised 2010 ada regulations please visit the department s website www ada gov.
The grab bar s shall be mounted 33 36 inches 840 915 mm above the shower floor measured at the entry. The icc a117 1 standard for accessible and usable buildings and facilities which is referenced by the international building code requires an 18 min. Specific questions call the toll free ada information line at 800 514 0301 voice or 800 514 0383. Grab bars shall be installed in a horizontal position 33 inches 840 mm minimum and 36 inches 915 mm maximum above the finish floor measured to the top of the gripping surface except that at water closets for children s use complying with 604 9 grab bars shall be installed in a horizontal position 18 inches 455 mm minimum and 27 inches 685 mm maximum above the finish floor measured to the top of the gripping surface.
Grab bars must be installed between 34 and 38 inches above the floor and there must be a separation between the grab bar and the wall surface of at least 1 1 2 inches. Alternate roll in type shower compartments in alternate roll in type shower compartments grab bars shall be provided on the back wall and the side wall farthest from the compartment entry. The controls shall be placed in an area between 38 48 inches 965 1220 mm above the floor. For more information for information about the ada including the revised 2010 ada regulations please visit the department s website www ada gov.
Or for answers to specific questions call the toll free ada information line at 800 514 0301 voice or 800 514 0383 tty. An ada compliant grab bar handrail must be fully anchored and have a smooth surface that can be easily grabbed. A 42 inches 1065 mm minimum length grab bar is required on the side wall spaced a maximum of 12 inches 305 mm from the back wall and extending a minimum of 54 inches 1370 mm from the back wall at a height of 33 36 inches 840 915 mm. Bathtubs without permanent seats.
The bar must be 1 1 4 to 1 1 2 inches in diameter. The toilet paper dispenser shall be mounted below the grab bar at a minimum height of 19 inches 485 mm. However ansi allows for 6 mm projection in the allowed area. For ada and ansi nothing can be installed directly behind the grab bar.